QUALITÄTSVERSPRECHEN
KAUF AUF RECHNUNG
ÜBER 200.000 ZUFRIEDENE KUNDEN

Victron MultiPlus-II 48/5000/70-50 230V GX

€1,140.00*

delivery time: 2-5 days

Product number: VBD70-50
Product information "Victron MultiPlus-II 48/5000/70-50 230V GX"

The Multiplus-II 48/5000/70-50 GX is a high-end device combination from Victron Energy (MPN PMP482506000) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 50 A and extends the potential range of use to ESS applications. The inverter module delivers a full 5000 W with a non-linear load and 4000 W with a linear continuous load. The 48 V battery charger is also very well proportioned with 70 A charging power and is supplemented by a 50 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Compared to the other devices in the series, the GX variants have an integrated GX display with numerous other connection options.

Important features of the Multiplus-II 48/5000/70-50 GX
Integrated GX control unit with various communication connections
PowerControl and PowerAssist to increase mains or generator output
built-in anti-islanding function and connection option for external current sensor (optional)
can be used as a backup device in grid-connected systems for power supply in the event of grid failures
can be used in various ESS (Energy Storage System) applications
ideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applications
VE.Bus interface for parallel and three-phase operation, remote monitoring and system integration
practically unlimited power thanks to parallel and three-phase operation
can be configured on site or remotely using VEConfigure software*


Technical features
5000W power with non-linear load 4000 W continuous load and 9000 W peak power
for 48 V battery voltage, 50 A transfer switch and 70 A battery charger
Output voltage: 230 VAC, frequency: 50 Hz
max. efficiency is 95%, protection class IP22


Always enough power thanks to PowerControl and PowerAssist
A maximum mains or generator current can be set on the MultiPlus-II 48/5000/70-50 GX. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries.

Solar power: alternating current even in the event of a mains failure
The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters.

Maximum flexibility thanks to two AC outputs
The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output.

Scope of the integrated GX device
A VE.Can interface This can be used to connect VE.Can devices from Victron (e.g. VE.Can MPPT). The connection can also be reconfigured via the remote console for use with a compatible CAN bus Li-ion battery.
1xUSB connection
1x Ethernet connection
1x VE.Direct connection
Many options for system expansion
The settings can be changed within a few minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel.

Remote configuration and monitoring
Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed.

Scope of delivery:

1x Victron PMP482506000 Multiplus-II 48/5000/70-50 GX 230V
1x operating instructions

AC-Ausgangsspannung: 230 V
AC Dauerleistung: 4000 W
Artikelgewicht: 29,00 Kg
Dimensions (L x W x H): 565 x 320 x 149 mm
EAN: 8719076048824
Gleichstromanschluss (DC): M8 Gewindebolzen
Hersteller: Victron Energy
Max. Ladestrom: 70A
Modell: MultiPlus-II 48/5000/70-50 230V
Modell-Nr.: PMP482505010
Tension: 48 V to 230 V
Wave type: Pure sine wave
Wirkungsgrad: bis 95%

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Ähnliche Artikel

Victron MultiPlus-II 48/10000/140-100/100 230V
Victron MultiPlus-II 48/10000/140-100/100 230V
The Multiplus-II 48/10000/140-100 is a high-end device combination from Victron Energy (MPN PMP483105000) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 100 A and extends the potential range of use to ESS applications. The inverter module delivers a full 10000 W with a non-linear load or 8000 W with a linear continuous load. The 48 V battery charger is also very well proportioned with 140 A charging power and is supplemented by a 100 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 48/10000/140-100 PowerControl and PowerAssist increase of mains or generator powerbuilt-in anti-islanding function and connection option for external current sensor (optional)can be used as a backup device in grid-connected systems for power supply in the event of grid failurescan be used in various ESS (Energy Storage System) applicationsideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applicationsVE.Bus interface for parallel and three-phase operation, remote monitoring and system integrationpractically unlimited power thanks to parallel and three-phase operationcan be configured on site or remotely using VEConfigure software* Technical features 10000 W power with non-linear load 8000 W continuous load and 18000 W peak powerfor 48 V battery voltage, 100 A transfer switch and 140 A battery chargerOutput voltage: 230 VAC, frequency: 50 HzMax. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 48/10000/140-100. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP483105000 Multiplus-II 48/10000/140-100A 1x operating instructions

€3,539.73*
Victron MultiPlus-II 48/5000/70-50 230V
Victron MultiPlus-II 48/5000/70-50 230V
The Multiplus-II 48/5000/70-50 is a high-end device combination from Victron Energy (MPN PMP482505010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 100 A and extends the potential range of use to ESS applications. The inverter module delivers a full 5000 W with a non-linear load and 4000 W with a linear continuous load. The 48 V battery charger is also very well proportioned with 70 A charging power and is supplemented by a 50 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 48/5000/70-50 PowerControl and PowerAssist increase of mains or generator powerbuilt-in anti-islanding function and connection option for external current sensor (optional)can be used as a backup device in grid-connected systems for power supply in the event of grid failurescan be used in various ESS (Energy Storage System) applicationsideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applicationsVE.Bus interface for parallel and three-phase operation, remote monitoring and system integrationpractically unlimited power thanks to parallel and three-phase operationcan be configured on site or remotely using VEConfigure software* Technical features 5000 W power with non-linear load 4000 W continuous load and 9000 W peak powerfor 48 V battery voltage, 50 A transfer switch and 70 A battery chargerOutput voltage: 230 VAC, frequency: 50 Hzmax. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 48/5000/70-50. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP482505010 Multiplus-II 48/5000/70-50A 1x operating instructions

€1,179.59*
Victron MultiPlus-II 12/3000/120-32 230V
Victron MultiPlus-II 12/3000/120-32 230V
The Multiplus-II 12/3000/120-32 is a high-end device combination from Victron Energy (MPN PMP122305010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 50 A. The inverter module delivers a full 3000 W with a non-linear load or 2400 W with a linear continuous load. The 12 V battery charger is also very well proportioned with 120 A charging power and is supplemented by a 32 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 12/3000/120-32 PowerControl and PowerAssist increase of mains or generator power Built-in anti-islanding function and connection option for external current sensor (optional) can be used as a backup device in grid-connected systems for power supply in the event of grid failures Can be used in various applications ideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applications VE.Bus interface for parallel and three-phase operation, remote monitoring and system integration practically unlimited power thanks to parallel and three-phase operation can be configured on site or remotely using VEConfigure software* Technical features 3000 W power with non-linear load 2400 W continuous load and 5500 W peak power for 12 V battery voltage, 32 A transfer switch and 120 A battery charger Output voltage: 230 VAC, frequency: 50 Hz Max. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 12/3000/120-32. The MultiPlus-II then takes account of other connected AC consumers and only uses the current that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP122305010 Multiplus-II 12/3000/120-32A1x operating instructions

€1,396.17*
Victron MultiPlus-II 12/3000/120-32 230V
Victron MultiPlus-II 12/3000/120-32 230V
The Multiplus-II 12/3000/120-32 is a high-end device combination from Victron Energy (MPN PMP122305010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 50 A. The inverter module delivers a full 3000 W with a non-linear load or 2400 W with a linear continuous load. The 12 V battery charger is also very well proportioned with 120 A charging power and is supplemented by a 32 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 12/3000/120-32 PowerControl and PowerAssist increase of mains or generator power Built-in anti-islanding function and connection option for external current sensor (optional) can be used as a backup device in grid-connected systems for power supply in the event of grid failures Can be used in various applications ideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applications VE.Bus interface for parallel and three-phase operation, remote monitoring and system integration practically unlimited power thanks to parallel and three-phase operation can be configured on site or remotely using VEConfigure software* Technical features 3000 W power with non-linear load 2400 W continuous load and 5500 W peak power for 12 V battery voltage, 32 A transfer switch and 120 A battery charger Output voltage: 230 VAC, frequency: 50 Hz Max. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 12/3000/120-32. The MultiPlus-II then takes account of other connected AC consumers and only uses the current that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP122305010 Multiplus-II 12/3000/120-32A1x operating instructions

€1,157.16*
Victron MultiPlus-II 48/3000/35-32 230V
Victron MultiPlus-II 48/3000/35-32 230V
The Multiplus-II 48/3000/35-32 is a high-end device combination from Victron Energy (MPN PMP482305010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 50 A and extends the potential range of use to ESS applications. The inverter module delivers a full 3000 W with a non-linear load and 2400 W with a linear continuous load. The 48 V battery charger is also very well proportioned with 35 A charging power and is supplemented by a 32 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 48/3000/35-32 PowerControl and PowerAssist increase of mains or generator power Built-in anti-islanding function and connection option for external current sensor (optional) can be used as a backup device in grid-connected systems for power supply in the event of grid failures can be used in various ESS (Energy Storage System) applications ideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applications VE.Bus interface for parallel and three-phase operation, remote monitoring and system integration practically unlimited power thanks to parallel and three-phase operation can be configured on site or remotely using VEConfigure software* Technical features 3000W power with non-linear load 2400 W continuous load and 6000 W peak power for 48 V battery voltage, 32 A transfer switch and 35 A battery charger Output voltage: 230 VAC, frequency: 50 Hz Max. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 48/3000/35-32. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP482305010 Multiplus-II 48/3000/35-32A1x operating instructions

€779.09*
Victron MultiPlus-II 24/3000/70-32 230V
Victron MultiPlus-II 24/3000/70-32 230V
The Multiplus-II 24/3000/70-32 is a high-end device combination from Victron Energy (MPN PMP242305010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 50 A and extends the potential range of use to ESS applications. The inverter module delivers a full 3000 W with a non-linear load or 2400 W with a linear continuous load. The 24 V battery charger is also very well proportioned with 70 A charging power and is supplemented by a 32 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 24/3000/70-32 PowerControl and PowerAssist increase mains or generator output built-in anti-islanding function and connection option for external current sensor (optional) can be used as a backup device in grid-connected systems for power supply in the event of grid failures can be used in various ESS (Energy Storage System) applications ideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applications VE.Bus interface for parallel and three-phase operation, remote monitoring and system integration practically unlimited power thanks to parallel and three-phase operation can be configured on site or remotely using VEConfigure software* Technical features 3000 W power with non-linear load 2400 W continuous load and 6000 W peak power for 24 V battery voltage, 32 A transfer switch and 70 A battery charger Output voltage: 230 VAC, frequency: 50 Hz Max. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 24/3000/70-32. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP242305010 Multiplus-II 24/3000/70-32A1x operating instructions

€1,396.17*
Victron MultiPlus-II 48/8000/110-100/100 230V
Victron MultiPlus-II 48/8000/110-100/100 230V
The Multiplus-II 48/8000/110-100 is a high-end device combination from Victron Energy (MPN PMP482805000) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 100 A and extends the potential range of use to ESS applications. The inverter module delivers a full 8000 W with a non-linear load and 6400 W with a linear continuous load. The 48 V battery charger is also very well proportioned with 110 A charging power and is supplemented by a 100 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the Multiplus-II 48/8000/110-100 PowerControl and PowerAssist - increase of mains or generator powerBuilt-in anti-islanding function and connection option for external current sensor (optional)can be used as a backup device in grid-connected systems for power supply in the event of grid failurescan be used in various ESS (Energy Storage System) applicationsideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applicationsVE.Bus interface for parallel and three-phase operation, remote monitoring and system integrationpractically unlimited power thanks to parallel and three-phase operationcan be configured on site or remotely using VEConfigure software* Technical features 8000 W power with non-linear load 6400 W continuous load and 15000 W peak powerfor 48 V battery voltage, 100 A transfer switch and 110 A battery chargerOutput voltage: 230 VAC, frequency: 50 HzMax. efficiency is 95%, protection class IP22 Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 48/8000/110-100. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP482805000 Multiplus-II 48/8000/110-100A 1x operating instructions

€2,958.64*
Victron MultiPlus-II 24/5000/120-50 230V 5000W inverter 120A charger All-in-One
Victron MultiPlus-II 24/5000/120-50 230V 5000W inverter 120A charger All-in-One
The Multiplus-II 24/5000/120-50A is a high-end device combination from Victron Energy (MPN PMP242505010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 100 A and extends the potential range of use to ESS applications. The inverter module delivers a full 5000 W with a non-linear load and 4000 W with a linear continuous load. The 24 V battery charger is also very well proportioned with 120 A charging power and is supplemented by a 50 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the MultiPlus-II 24/5000/120-50 PowerControl and PowerAssist increase of mains or generator powerBuilt-in anti-islanding function and connection option for external current sensor (optional)can be used as a backup device in grid-connected systems for power supply in the event of grid failurescan be used in various ESS (Energy Storage System) applicationsideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applicationsVE.Bus interface for parallel and three-phase operation, remote monitoring and system integrationpractically unlimited power thanks to parallel and three-phase operationCan be configured on site or remotely using VEConfigure software Technical features 5000 W power with non-linear load 4000 W continuous load and 9000 W peak powerfor 24 V battery voltage, 50 A transfer switch and 120 A battery chargerOutput voltage: 230 VAC, frequency: 50 HzMax. efficiency is 95%, protection class IP22Note: Not standardized according to EN 50-549Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 24/5000/120-50. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP242505010 Multiplus-II 24/5000/120-50A 1x operating instructions

€2,222.85*
Victron MultiPlus-II 24/5000/120-50 230V 5000W inverter 120A charger All-in-One
Victron MultiPlus-II 24/5000/120-50 230V 5000W inverter 120A charger All-in-One
The Multiplus-II 24/5000/120-50A is a high-end device combination from Victron Energy (MPN PMP242505010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and PowerAssist functions to 100 A and extends the potential range of use to ESS applications. The inverter module delivers a full 5000 W with a non-linear load and 4000 W with a linear continuous load. The 24 V battery charger is also very well proportioned with 120 A charging power and is supplemented by a 50 A transfer switch, which can be used to switch back and forth between the AC connections at lightning speed. Important features of the MultiPlus-II 24/5000/120-50 PowerControl and PowerAssist increase of mains or generator powerBuilt-in anti-islanding function and connection option for external current sensor (optional)can be used as a backup device in grid-connected systems for power supply in the event of grid failurescan be used in various ESS (Energy Storage System) applicationsideally suited for professional seafaring, yachts, vehicles and land-based, off-grid applicationsVE.Bus interface for parallel and three-phase operation, remote monitoring and system integrationpractically unlimited power thanks to parallel and three-phase operationCan be configured on site or remotely using VEConfigure software Technical features 5000 W power with non-linear load 4000 W continuous load and 9000 W peak powerfor 24 V battery voltage, 50 A transfer switch and 120 A battery chargerOutput voltage: 230 VAC, frequency: 50 HzMax. efficiency is 95%, protection class IP22Note: Not standardized according to EN 50-549Always enough power thanks to PowerControl and PowerAssist A maximum mains or generator current can be set on the MultiPlus-II 24/5000/120-50. The MultiPlus-II then takes account of other connected AC consumers and only uses the power that is still "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The PowerAssist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such cases, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. If the load is reduced, i.e. consumers are switched off, the available energy can then be used to recharge the batteries. Solar power: alternating current even in the event of a mains failure The device can be used with both off-grid and grid-connected PV systems as well as other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters. Maximum flexibility thanks to two AC outputs The main output ensures uninterrupted operation. In the event of a mains failure or an interruption in the shore/generator current, the MultiPlus-II takes over the supply to the connected loads. The switchover takes place so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic devices is guaranteed. The second output only supplies power when alternating current is available at the input of the MultiPlus-II. Consumers that must not discharge the battery, such as a water heater, can be connected to this output. Many options for system expansion The settings can be changed in a matter of minutes using the VEConfigure software (a computer or laptop and an MK3 USB interface are required) and several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart Dongle), battery monitor, Digital Multi control panel. Remote configuration and monitoring Install a Color Control GX or other GX products to connect to the Internet. The operating data can be stored and viewed free of charge on our VRM (Victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed. Scope of delivery: 1x Victron PMP242505010 Multiplus-II 24/5000/120-50A 1x operating instructions

€1,842.01*