Dual charger WITH start bypass
It is not uncommon for two independent battery circuits or two different battery types to require special mains chargers with correspondingly different charging capacities. This usually means that in addition to the "normal" charger for the starter battery, an additional device must be installed for the special on-board battery - withall its attendant consequences: Additional costs for the device, additional effort for installation and double the space required in the vehicle.
The VAC-Duo charger series, which combines two separate, independently operating charging units in one space-saving device, provides a remedy. Each charger can be set precisely to the battery type, charging program and battery capacity. This means that a fully-fledged charger is also available for the starter battery.
As with all chargers in the VAC series, the electronics are protected against moisture and the 825 temperature sensors are included in the scope of delivery. The +86 signal output is also available to prevent the engine from starting when the vehicle is connected to the mains.
As a further special feature, devices with an integrated 200 A battery bypass function are available, which enable an emergency engine start. This function can also be operated remotely via a simple pushbutton switch, e.g. from the dashboard.
Product features:
- High operational safety
- Fast, battery-friendly charging for long battery life
- Small, light and compact
- Full charging power even at low mains voltage
- Automatic battery regeneration
- Monitoring-free charging
- Temperature compensation
- Suitable for buffer operation
- Built-in mains charger specially designed for rescue vehicles
- Two completely separate, independent charging sections
- Optimized 6-stage charging characteristic for acid, gel and AGM batteries
- Adjustable battery type and capacity yes battery
- Signal output for engine start inhibit
- Electronics protected against moisture
- With emergency start function / start bypass function 200 A
Technical data:
- Charging capacity 12 V / 20 A + 30 A
- Nominal voltage (AC) 230 V
- Operating voltage range (AC) 190 V - 265 V (full charging capacity)
- Power consumption (AC) max. 720 W
- Nominal battery voltage (DC) 12 V
- Battery capacity 50 - 230 Ah / 75-350 Ah
- For further technical data, please refer to the data sheet!
Scope of delivery:
- Automatic Charger VAC 1220/30 Duo with emergency start function
- Mains cable
- 2 temperature sensors
- Operating instructions
| Ambient temperature: | -20 ˚C to +50 ˚C |
|---|---|
| Anzahl Ladeausgänge: | 2 |
| DC input voltage: | 12 V |
| Dimensions (L x W x H): | 305 x 90 x 265 mm |
| For battery capacity: | 50 - 230 Ah / 75 - 350 Ah |
| Für Batterieart: | AGM (VRLA), Gel (VRLA), Li-Ion (LiFePO4), Nass (Flüssig), SLA |
| Ladekennlinie: | Auf Batterie angepasst je nach Einstellung |
| Material: | Aluminium |
| Tension: | 12V to 12V |
| Max. Ladestrom: | 20A, 40 A |
| Schutzklasse: | IP21 |
| Hersteller: | VOTRONIC |
| Modell-Nr.: | 0633 |
0 of 0 reviews
Average rating of 0 out of 5 stars
Login

Gebrauchsanleitung lesen, beachten und aufbewahren. Diese finden Sie auf die Rückseite der Batterie geklebt oder über einen QR-Code, der auf die Herstellerwebsite führt.

Augenschutz: Bei Arbeiten an der Batterie immer eine Schutzbrille tragen. Schutzhandschuhe und Schutzkleidung tragen.

Außer Reichweite von Kindern aufbewahren. Darf nicht in die Hände von Kindern gelangen.

Explosionsgefahr. Batterien erzeugen während und nach dem Laden ein hochexplosives Gasgemisch. Nicht in luftdichten Containern betreiben. An nicht gut belüfteten Orten Gasableitungsschlauch verwenden.

Offenes Feuer und Funkenbildung ausschließen. Antistatische Tücher und Kleidung sowie isolierte Werkzeuge verwenden. Nicht rauchen in der Nähe von Batterien.

Korrosions- und Verätzungsgefahr. Enthält Schwefelsäure-Gemisch. Augen, Haut und Kleidung schützen. Batterien aufrecht halten, um Austritt zu vermeiden. Niemals öffnen.

Batterieentsorgung
Enthält mehr als 0,004 Masseprozent des Schadstoffes Blei. Nicht in den Hausmüll geben. Sie können Ihre Batterien kostenlos beim Verkäufer, bei Verkäufern Batterien gleicher Art oder an öffentlichen Sammelstellen abgeben. Vor Entsorgung mindestens einen Pol isolieren.

Erste Hilfe: Beim Kontakt von Batteriesäure mit Haut oder Augen betroffene Stellen sofort mit klarem Wasser mehrere Minuten lang gründlich spülen. Danach unverzüglich einen Arzt aufsuchen. Bei Aufnahme über den Mund sofort ärztliche Versorgung veranlassen. Säure auf Haut oder Kleidung sofort mit Seifenlauge oder Säureumwandler neutralisieren und mit viel Wasser nachspülen.
Ladung und Lagerung: Nie beide Gasaustrittsöffnungen verschlossen lassen. Stets einen Pol abdecken, um Kurzschlüsse zu vermeiden. Niemals gefroren oder mit Temperatur von über 45 °C laden. Bei Überhitzung Ladevorgang sofort unterbrechen. Pole und Anschlussklemmen vor Korrosion schützen.
Accessory Items