Votronic 3324 VCC 1212-30 12V to 12V 30A B2B charging converter
€174.91*
No longer available
Product information "Votronic 3324 VCC 1212-30 12V to 12V 30A B2B charging converter"
The VCC 1212-30 from Votronic (MPN 3324) is a fully automatic, non-isolated battery charging converter for special vehicles, high-quality motorhomes and boats.
- High charging capacity even for short journeys or full charging for longer journeys.
- Increases/reduces the voltage to the required level in order to charge the on-board battery precisely with the optimum charging characteristic.
- Fully compensates for line losses and voltage fluctuations in the alternator, such as those that constantly occur to a considerable extent in Euro 6 vehicles (intelligent alternators).
- Compact design, low weight (high-frequency switch mode technology) and powerfully dimensioned power components for safe operation.
- Significantly better energy balance of the on-board battery without interfering with the starter circuit
- Supplied 12 V consumers are protected against overvoltage and voltage fluctuations.
- The charging voltage is free of peaks and regulated in such a way that the batteries cannot be overcharged.
- Fully automatic operation: The device is permanently connected to the batteries and is automatically activated by the vehicle's running alternator. The batteries are not discharged when the engine is not running.
- Parallel and buffer operation: The battery continues to be charged or is kept fully charged during simultaneous consumption. The device automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, malfunction and battery reverse discharge through electronic cut-off up to complete disconnection of device and battery.
- Built-in on-board filter: Problem-free parallel operation with other charging sources (EBL, chargers, engine and fuel generators, solar systems) on one battery.
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
- Connection for battery temperature sensor (included): For lead-acid batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, resulting in a better full charge of the weaker battery in cold weather and avoiding unnecessary battery gassing in summer temperatures.
- LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C.
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on
Scope of delivery:
- Votronic 3324 VCC 1212-30 12V to 12V 30A B2B charging converter
- Temperature sensor
- Operating instructions
| Ausgangsspannung: | 12 V |
|---|---|
| DC input voltage: | 12 V |
| Dimensions (L x W x H): | 146 x 67 x 40 mm |
| Für Batterieart: | AGM (VRLA), Gel (VRLA), Li-Ion (LiFePO4), Nass (Flüssig) |
| Galvanisch isoliert: | ja |
| Ladewandler-Ladestrom (A): | 30 A |
| Max. Ladeleistung: | 360W |
| Tension: | 12V to 12V |
| Modell-Nr.: | 3324 |
0 of 0 reviews
Average rating of 0 out of 5 stars
Login

Gebrauchsanleitung lesen, beachten und aufbewahren. Diese finden Sie auf die Rückseite der Batterie geklebt oder über einen QR-Code, der auf die Herstellerwebsite führt.

Augenschutz: Bei Arbeiten an der Batterie immer eine Schutzbrille tragen. Schutzhandschuhe und Schutzkleidung tragen.

Außer Reichweite von Kindern aufbewahren. Darf nicht in die Hände von Kindern gelangen.

Explosionsgefahr. Batterien erzeugen während und nach dem Laden ein hochexplosives Gasgemisch. Nicht in luftdichten Containern betreiben. An nicht gut belüfteten Orten Gasableitungsschlauch verwenden.

Offenes Feuer und Funkenbildung ausschließen. Antistatische Tücher und Kleidung sowie isolierte Werkzeuge verwenden. Nicht rauchen in der Nähe von Batterien.

Korrosions- und Verätzungsgefahr. Enthält Schwefelsäure-Gemisch. Augen, Haut und Kleidung schützen. Batterien aufrecht halten, um Austritt zu vermeiden. Niemals öffnen.

Batterieentsorgung
Enthält mehr als 0,004 Masseprozent des Schadstoffes Blei. Nicht in den Hausmüll geben. Sie können Ihre Batterien kostenlos beim Verkäufer, bei Verkäufern Batterien gleicher Art oder an öffentlichen Sammelstellen abgeben. Vor Entsorgung mindestens einen Pol isolieren.

Erste Hilfe: Beim Kontakt von Batteriesäure mit Haut oder Augen betroffene Stellen sofort mit klarem Wasser mehrere Minuten lang gründlich spülen. Danach unverzüglich einen Arzt aufsuchen. Bei Aufnahme über den Mund sofort ärztliche Versorgung veranlassen. Säure auf Haut oder Kleidung sofort mit Seifenlauge oder Säureumwandler neutralisieren und mit viel Wasser nachspülen.
Ladung und Lagerung: Nie beide Gasaustrittsöffnungen verschlossen lassen. Stets einen Pol abdecken, um Kurzschlüsse zu vermeiden. Niemals gefroren oder mit Temperatur von über 45 °C laden. Bei Überhitzung Ladevorgang sofort unterbrechen. Pole und Anschlussklemmen vor Korrosion schützen.
Accessory Items